The green line is the performance of the wall.
Stc rating for concrete walls.
Stc hollow with insulation 52 53 56 59 corefoam masonry foam insulationis an excellent product for improving thermal and acoustic properties of walls constructed with concrete masonry units cmu.
The magenta line in that graph is the standard reference stc contour.
The stc rating of a cmu wall can be estimated based on its weight using the following formula.
Installing insula tion within a wall or floor ceiling cavity will improve the stc rating by about 4 6 db which is clearly noticeable1.
Stc 0 18w 40 where w pounds per square foot psf this information is provided as a tool to help estimate.
The estimate could easily be off by as much as 4 db.
Stc ratings for wall floor and window materials and assemblies 3 appendix a stc ratings a 1 walls a 1 exterior a 1 interior a 9 wooden studs a 9 metal studs a 14 floors a 16 wood a 16 concrete a 21 windows a 24 doors a 27 exterior a 27 interior a 29 appendix b references b 1.
Because coarse textured units may allow airborne sound to enter the wall they require a surface treatment to seal at least one side of the wall.
Standard method for determining sound transmission ratings for masonry walls tms 0302 ref.
Simple concrete slabs with density around 2300 kg m 3 and thickness in the range 150 to 200 mm provide stcs from about 53 to 58.
1 contains procedures for determining stc values of.
When the mass of a barrier is doubled the isolation quality or stc rating increases by approximately 5 db which is clearly noticeable.
Adding green glue to boths side of a wall.
If your wall graph is closest to a standard stc 35 curve your wall is said to have an stc rating of 35.
For example a thick concrete wall will block more sound than a thin gypsum 2x4 wall.
Helps ensure that partition sound performance matches the promise of sound tests by sealing off spaces at partition perimeters and around cutouts can increase the stc rating of a double layer steel framed partition from 29 to 53 stc an integral part of high performance usg partition designs for attenuation of low frequency sound from machinery and music suitable for use at the perimeter of fire rated wall assemblies for more information see the following brochure.
There are numerous other issues that need to be addressed to get a more accurate.
Stc 14 1w equation 1 is applicable to uncoated fine or medium textured concrete masonry and to coated coarse textured concrete masonry.
In the absence of test data standard calculation methods exist which tend to be conservative.
A wide variety of stc ratings is available with concrete masonry construction depending on wall weight wall construction and finishes.
Mass is commonly added to existing walls by adding additional layers of gypsum.
The standard requires a minimum laboratory stc rating of 50 for party walls and floor ceilings.